Top

6500-24 24 Zone Digital

  • All digital design, with outputs for printer, computers, and LANs
  • Rugged Membrane Face Plate
  • Backward Compatibility with 630, 6300 Series
  • Define-able Zone Names for easy to review printouts and logs
  • At-A-Glance Viewing of Status of ALL Zones
  • Plus Output Capabilities:
    • Printer / Serial Ports, RS-232; RS-485
    • Ethernet Connection Option
  • Recessed Switches and Lights in Sealed Membrane Keypad
  • Uses Existing Zone Wiring for 6300-24 Annunciators
  • Optional Added Line Security using Dual Resistors
    • 4 States: Trouble (Open) / Normal / Alarm / Trouble (Short)
  • Annunciates Zone (door) Status and new Fault Status
    • Even in Access Mode
  • Logs Events to Printer and File
  • Easy Programming
  • Use Zone Names Feature for Better Printouts and Logs
6500-24 24 Zone Digital Annunciator

6500-24 24 Zone Digital Annunciator

UPGRADE EXISTING 630 AND 6300 SERIES

The new system provides more reporting and tamper monitoring, even in access mode. Door status is displayed in both access and secure modes. Line tampering is also reported in both modes.

WORK FROM THE INSTALLED BASE

Use the existing wires and sensors. To upgrade to the higher security, add a resistor to the existing sensors. More security with no new cabling required.

ALL EVENTS ARE RECORDED TO A PRINTER / DATA PORT

Size: 19″W x 5.25″H x 10″D ( 48.25 x 13.3 x 25.4 cm) (plus connectors); rack mount case

Power: 115 / 230 V, 50/60 Hz; internal voltage selector switch; onboard switching regulated supply

Backup Battery: 12V, 4.5AH, lead acid gel type

NOTE: At your request, we will NOT INCLUDE this battery, which cannot ship via pouch. Contact AES for details

Zone Inputs: 24 individual zones

Line Security:

  • Advanced Mode: 4 levels; Normal, Alarm, Trouble Short, Trouble Open
  • Classic Mode: 3 levels; Normal, Alarm Short, Alarm Open

Switches:

  • Access/Secure: 24, one for each zone; Push button membrane switch; Push-Toggle
  • Access mode (yellow light ON) zone activity is not annunciated or recorded.
  • Secure mode (yellow light OFF) annunciates and records all events – alarm, restore,silence, reset
  • Test Switch: Tests all zones by simulating an imbalance on all input lines
  • Silence Switch: Shuts off audible signal; red alarm light stay (memory mode)
  • Reset Switch: Resets all zones; Clears red light (memory mode)

Indicators:

  • Red Lights, 1 per zone: ON indicates an alarm condition; OFF indicates normalcondition
    • Blinking light indicates un-silenced alarm
    • Steady light indicates memory mode following silenced alarm, Reset clearssteady light
    • Double Blinking light indicates a line trouble; trouble is reported in both Access andSecure Modes
  • Yellow Lights, 1 per zone: ON indicates a zone in Access Mode; OFF indicates zonein Secure Mode
  • Green Lights, AC and BATT:
    • ON indicates OK
    • BLINK indicates AC or Battery failure
    • OFF indicates unit is off

Zone Inputs, 24:

  • Base unit has 50 pin connector; compatible with 6300-24-DSR annunciators
  • Easy upgrade to existing 6300 series annunciator installations:
    simply add a 3.01K resistor across the N.C. contact
  • Output board has cage clamp connectors; may be DIN mounted remote from the panel; order #6511 remote kit which includes 19″ DIN rail for rack use, and a 5-foot cable with 50-pin connectors to link remote terminal board to panel.

Resistors: 2 per zone; 3.01 K ohm, 1%

  • 3.01K = Normal; 6.02K = Alarm; Short = Trouble; Open = Trouble

Processor: 386 embedded micro; real time clock, DOS operating system

Ports:

  • Terminal I/O Port (RS-485 option, future use)
  • RS-232 Serial / Printer Port
  • Network Interface (future use)

Fuses:

  • AC Input 3 Amp
  • Battery 3 Amp

Printer Output:

  • Logs all events by zone and button push, with time, date.
  • Alarms, Restorals reported for any zone in Secure Mode
  • Line Trouble reported for any zone in Secure or Access Mode
  • AC Fail, Battery Fail
  • Pushing of Silence and Reset Buttons
  • Option #6525-80, Dot Matrix Printer, 80 column, serial input
HQ_DownloadDatasheet