7788F-C RF Subscriber

A fire subscriber, with 8 programmable EOL inputs, that meets UL requirements for Canada.

The 7788F-C Subscriber Unit is an AES-IntelliNet RF Communicator, which is used to link an alarm panel to an alarm monitoring central station. This subscriber unit is ULC listed for commercial fire alarm monitoring.

  • The 7788F-C has 8 wired inputs
  • All 8 inputs are End of Line (EOL) resistor type
  • Normally open relay on board for Acknowledge Delay/Antenna Cut/Low Battery/Charger Fail Output
  • Separate power no longer required for the Zone input module as was required on the 7750F-4X4 and 7750F-8 which this replaces
  • AC Failure Random Reporting Delay
  • Transceiver power PTC is added
  • Remote programming using software at the Central Station is disabled when Trouble Packets are enabled
  • 77 LED Status Board provides visual information
  • 707 LBD Board ensures that a low battery, that cannot be charged, will not be used affecting the unit RF communications
  • Easy to install

data-sheet-iconmanual-icon
  • 13.25” H x 8.5” W x 4.3” D (34 x 21.5 x 11 cm) excluding antenna
  • 5.8 lbs (2.6 kg) without battery (with battery add 6 lbs)
  • 16.5 VAC, 40VA class 2 (dry source only)
  • 12 VDC nominal
  • 150mA standby; 1.0A transmit
  • With AES-7794 full data accessory option, 210mA standby; 1.3A transmit (2 Watt transceiver)
  • Operating Temp:  0° to 49°C (32° to 120°F)
  • Storage Temp:  -10° to 60°C (14° to 140°F)
  • Relative Humidity: 0 to 85% RHC, Non Condensing
  • Backup Battery: 12V, 10AH (min) (24 hour standby), lead acid gel type required for all installations
  • Onboard self-resetting fuse, not serviceable
  • 8 Supervised individually programmable zones, all 8 are EOL type with Trouble & Restore
  • Low Battery Reporting: Below 11.5V 2.75 Minute Test Cycle (approx.), low battery disconnect 10V, reconnect 12V
  • AC Failure Reporting
  • Antenna Cut/Low Battery/Charger Fail Local Reporting
  • Reset button located on the PCB
  • Transceiver:  Standard UHF Frequency Ranges (410-440MHz, 440-470MHz, 470-512MHz)
  • Transceiver Fuse: 400 milliamp PTC, not serviceable
  • Standard RF Output Power: 2 Watts and 5 Watts
  • Zone 1-8: Dry contact supervised with 2.2K EOL resistor
  • Ground Fault: As tested by ULC is when an isolated ground terminal of a Supervised zone labeled “G” is less than 0.1 Ohm impedance to Earth Ground
  • 7041 – Hand Held Subscriber Programmer
  • 7794 – AES-IntelliPro Fire full data module