All digital design, with outputs for printer, computers, and
LANs
• Rugged Membrane Face Plate
• Backward Compatibility with 630, 6300 Series
• Define-able Zone Names for easy to review printouts
and logs
•
At-A-Glance Viewing of Status of ALL Zones
• Plus Output Capabilities:
- Printer / Serial Ports, RS-232; RS-485
- Ethernet Connection Option
• Recessed Switches and Lights in Sealed Membrane Keypad
• Uses Existing Zone Wiring for 6300-24 Annunciators
• Optional Added Line Security using Dual Resistors
- 4 States: Trouble (Open) / Normal / Alarm / Trouble (Short)
• Annunciates Zone (door) Status and new Fault Status
- Even in Access Mode
• Logs Events to Printer and File
• Easy Programming
• Use Zone Names Feature for Better Printouts and Logs
UPGRADE
EXISTING 630 AND 6300 SERIES
The new system provides
more reporting and tamper monitoring, even in
access mode. Door status is displayed in both access and secure
modes.
Line tampering is also reported in both modes.
WORK FROM THE INSTALLED BASE
Use the existing wires and sensors. To upgrade to the higher
security, add a resistor to the existing sensors. More security
with no new cabling required.
ALL EVENTS ARE RECORDED TO A PRINTER / DATA PORT
Size:
19”W x 5.25”H x 10”D ( 48.25 x 13.3 x 25.4
cm) (plus connectors); rack mount case
Power: 115 / 230 V, 50/60 Hz; internal voltage
selector switch; onboard switching
regulated supply
Backup Battery: 12V, 4.5AH, lead acid gel
type
Zone Inputs: 24 individual zones
Line Security:
• Advanced
Mode: 4 levels; Normal, Alarm, Trouble Short, Trouble Open
• Classic
Mode: 3 levels; Normal, Alarm Short, Alarm Open
Switches:
• Access/Secure: 24, one for each zone; Push button
membrane switch; Push-Toggle
Access mode (yellow light ON) zone activity is not annunciated
or recorded.
Secure mode (yellow light OFF) annunciates and records all
events - alarm, restore,
silence, reset
• Test Switch: Tests all zones by simulating an imbalance
on all input lines
• Silence Switch: Shuts off audible signal; red alarm
light stay (memory mode)
• Reset Switch: Resets all zones; Clears red light (memory
mode)
Indicators:
• Red Lights, 1 per zone: ON indicates an alarm condition;
OFF indicates normal
condition
- Blinking light indicates un-silenced alarm
- Steady light indicates memory mode following silenced alarm,
Reset clears
steady light
- Double Blinking light indicates a line trouble; trouble
is reported in both Access and
Secure Modes
• Yellow Lights, 1 per zone: ON indicates a zone in
Access Mode; OFF indicates zone
in Secure Mode
• Green Lights, AC and BATT:
- ON indicates OK
- BLINK indicates
AC or Battery failure
- OFF indicates
unit is off
Zone Inputs, 24:
• Base unit has 50 pin connector; compatible with 6300-24-DSR
annunciators
• Easy upgrade to existing 6300 series annunciator installations:
simply add a 3.01K resistor across the N.C. contact
• Output board has cage clamp connector; may be remoted
from panel, DIN mount
• Resistors: 2 per zone; 3.01 K ohm, 1%
- 3.01K = Normal; 6.02K = Alarm; Short = Trouble; Open = Trouble
Processor: 386 embedded micro; real time
clock, DOS operating system
Ports:
• Terminal I/O Port (RS-485 option, future use)
• RS-232 Serial / Printer Port
• Network Interface (future use)
Fuses:
• AC Input 3 Amp
• Battery 3 Amp
Printer Output: Logs all events by zone and
button push, with time, date.
• Alarms, Restorals reported for any zone in Secure
Mode
• Line Trouble reported for any zone in Secure or Access
Mode
• AC Fail, Battery Fail
• Pushing of Silence and Reset Buttons
Download